The Daikin FCA125C-CC2V 12.5kW inverter cassette air conditioner offers superior cooling and heating efficiency in a sleek, compact design. This reverse cycle cassette system features a 1-phase power supply and R32 refrigerant, ensuring optimal performance for Australian conditions. With quiet operation and advanced controls, it is the ideal choice for both residential and commercial spaces seeking reliable climate control.
Indoor: FCA125CVMA
Outdoor: RZAC125C2V1
Fascia: BYCQ125EAF
Wired Controller: BRC1E63
| Indoor Unit | FCA125CVMA | |||||||
| Outdoor Unit | RZAC125C2V1 | |||||||
| Power Supply | ø / V / Hz | 1 Phase, 220-240V, 50 Hz | ||||||
| Cooling Capacity | Rated (Min – Max) | kW | 12.5 (4.0 – 14.0) | |||||
| Heating Capacity | Rated (Min – Max) | kW | 14.0 (4.1 – 16.0) | |||||
| Power Consumption | Cooling | kW | 3.53 | |||||
| Heating | kW | 3.63 | ||||||
| Enery Efficiency | EER | kW | 3.54 | |||||
| COP | kW | 3.86 | ||||||
| Indoor Unit | Colour | Unit | – | |||||
| Decoration Panel | Fresh White | |||||||
| Airflow Rate (H / HM / M / ML / L) | L/s | 608 / 558 / 500 / 442 / 383 | ||||||
| m³/min | 36.5 / 33.5 / 30.0 / 26.5 / 23.0 | |||||||
| Sound Pressure Level (H / HM / M / ML / L) | dB(A) | 46.0 / 43.5 / 41.0 / 38.5 / 36.0 | ||||||
| Dimensions (HxWxD) | Unit | mm | 298 x 840 x 840 | |||||
| Decoration Panel | mm | 50 x 950 x 950 | ||||||
| Machine Weight | Unit | kg | 26 | |||||
| Decoration Panel | kg | 5.5 | ||||||
| Certified Operation Range | Cooling | °CWB | 14 to 25 | |||||
| Heating | °CDB | 15 to 27 | ||||||
| Outdoor Unit | Colour | Ivory white | ||||||
| Compresser | Type | Hermetically sealed swing type | ||||||
| Motor output | kW | 3.3 | ||||||
| Refrigerant Charge (R410a) | kg | 2.9 (charged for 30m) | ||||||
| Sound Level | Cooling / Heating | dB(A) | 53 / 56 | |||||
| Night quiet mode | dB(A) | 49 | ||||||
| Sound Power Level (H/L) | dB(A) | – | ||||||
| Dimensions (HxWxD) | mm | 990 x 940 x 320 | ||||||
| Machine Weight | kg | 78 | ||||||
| Certified Operation range | Cooling | °CDB | -5 to 46 | |||||
| Heating | °CWB | -15 to 15.5 | ||||||
| Piping Connections | Liquid (Flare) | mm | ø9.5 | |||||
| Gas (Flare) | mm | ø15.9 | ||||||
| Drain | Indoor Unit | mm | I.D. ø25 x O.D ø32 | |||||
| Outdoor Unit | mm | ø26.0 (Hole) | ||||||
| Refrigerant | R32 | |||||||
| Max, interunit piping length | m | 50 (Equivalent length 70) | ||||||
| Max. Installation level difference | m | 30 | ||||||
| Heat insulation | Both liquid and gas piping | |||||||