{"product_id":"fujitsu-set-auth45krta-t5-12-5kw-inverter-cassette-split-systems-1-phase-r32","title":"Fujitsu SET-AUTH45KRTA-T5 12.5kW Inverter Cassette Split Systems 1 Phase | R32","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch2\u003eThe Fujitsu SET-AUTH45KRTA-T5 12.5kW Inverter Cassette Split System 1 Phase\u003c\/h2\u003e\n\u003cp\u003eExperience unparalleled comfort with the Fujitsu SET-AUTH45KRTA-T5 12.5kW inverter cassette split system air conditioner. Designed for efficiency and reliability, this system features a powerful 12.5kW cooling capacity and a robust 14kW heating capacity, perfect for Australian climates. With a sleek cassette design, it integrates seamlessly into any space, providing quiet operation and advanced moisture control for optimal indoor air quality. Ideal for both residential and commercial settings, it ensures year-round comfort with minimal energy consumption.\u003c\/p\u003e\n\n\u003cp\u003eIndoor: AUTH45KRTA\u003cbr\u003eOutdoor: AOTH45KBTA\u003cbr\u003eGrille: UTG-UKTB-W\u003cbr\u003eController: Wired UTY-RNRYT5\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor unit\u003c\/td\u003e\n    \u003ctd\u003eAUTH45KRTA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor unit\u003c\/td\u003e\n    \u003ctd\u003eAOTH45KBTA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperation Type\u003c\/td\u003e\n    \u003ctd\u003eReverse Cycle\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePower Source\u003c\/td\u003e\n    \u003ctd\u003e230 \/ 1 \/ 50\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCooling Capacity\u003c\/td\u003e\n    \u003ctd\u003e12.50 (4 – 14)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHeating Capacity\u003c\/td\u003e\n    \u003ctd\u003e14.00 (4.2 – 16.5)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eInput Power Cooling\u003c\/td\u003e\n    \u003ctd\u003e3.89 (4.9)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eInput Power Heating\u003c\/td\u003e\n    \u003ctd\u003e3.44 (4.9)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEER Cooling\u003c\/td\u003e\n    \u003ctd\u003e3.21\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCOP Heating\u003c\/td\u003e\n    \u003ctd\u003e4.07\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eStar Rating Cooling\u003c\/td\u003e\n    \u003ctd\u003e3 \/ 3 \/ 3\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eStar Rating Heating\u003c\/td\u003e\n    \u003ctd\u003e3.5 \/ 2.5 \/ 2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTotal Cooling Seasonal Performance Factor Residential\u003c\/td\u003e\n    \u003ctd\u003e4.764 \/ 4.548 \/ 4.842\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHeating Seasonal Performance Factor Residential\u003c\/td\u003e\n    \u003ctd\u003e5.119 \/ 5.331 \/ 5.773\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTotal Cooling Seasonal Performance Factor Commercial\u003c\/td\u003e\n    \u003ctd\u003e5.119 \/ 5.331 \/ 5.773\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHeating Seasonal Performance Factor Commercial\u003c\/td\u003e\n    \u003ctd\u003e5.139 \/ 4.658 \/ 4.043\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRunning Current\u003c\/td\u003e\n    \u003ctd\u003e17.1 \/ 15\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMoisture Removal\u003c\/td\u003e\n    \u003ctd\u003e4.8\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor Sound Pressure Cooling\u003c\/td\u003e\n    \u003ctd\u003e46 \/ 36\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor Sound Pressure Heating\u003c\/td\u003e\n    \u003ctd\u003e46 \/ 36\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor Sound Pressure\u003c\/td\u003e\n    \u003ctd\u003e55 \/ 57\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor Sound Power\u003c\/td\u003e\n    \u003ctd\u003e71\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eAir Circulation (Indoor – High Fan) Cooling\u003c\/td\u003e\n    \u003ctd\u003e542\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eAir Circulation (Indoor – High Fan) Heating\u003c\/td\u003e\n    \u003ctd\u003e542\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor Unit Dimensions\u003c\/td\u003e\n    \u003ctd\u003e288 x 840 x 840\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor Unit Weight\u003c\/td\u003e\n    \u003ctd\u003e29\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor Unit Dimensions\u003c\/td\u003e\n    \u003ctd\u003e998 x 940 x 320\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n    \u003ctd\u003e67\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eGrill Weight\u003c\/td\u003e\n    \u003ctd\u003e6\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePiping Connects\u003c\/td\u003e\n    \u003ctd\u003e9.52 \/ 15.88\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePipe Length\u003c\/td\u003e\n    \u003ctd\u003e50 (30)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMax Height Difference\u003c\/td\u003e\n    \u003ctd\u003e30\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperation Range Cooling\u003c\/td\u003e\n    \u003ctd\u003e-10 to 50\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperation Range Heating\u003c\/td\u003e\n    \u003ctd\u003e-15 to 24\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n    \u003ctd\u003eR32\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRefrigerant Amount\u003c\/td\u003e\n    \u003ctd\u003e2,700\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Fujitsu","offers":[{"title":"Default Title","offer_id":47123493978268,"sku":"SET-AUTH45KRTA-T5","price":4774.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0248\/9756\/files\/Complete_Set_6_a3efb629-4774-4829-9885-94f6d2b866b1.png?v=1782728273","url":"https:\/\/checkout.airconditioningexperts.com.au\/products\/fujitsu-set-auth45krta-t5-12-5kw-inverter-cassette-split-systems-1-phase-r32","provider":"Air Conditioning Experts","version":"1.0","type":"link"}