{"product_id":"fujitsu-set-auth36krta-3ph-yc-10kw-inverter-cassette-split-systems-1-phase-r32","title":"Fujitsu SET-AUTH36KRTA-3PH-YC 10kW Inverter Cassette Split Systems 3 Phase | R32","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch2\u003eFujitsu SET-AUTH36KRTA 10kW Inverter Cassette Split System 3 Phase\u003c\/h2\u003e\u003cp\u003eThe Fujitsu SET-AUTH36KRTA 10kW inverter cassette split system air conditioner offers exceptional climate control with a powerful 3-phase, reverse cycle operation. It is equipped with an advanced grille and wired controller, delivering 10kW of efficient cooling and 11.2kW heating capacity. With its quiet operation and high moisture removal, it is ideal for both residential and commercial spaces. Durable and efficient, this system ensures consistent comfort with minimal disruption.\u003c\/p\u003e\u003cp\u003eIndoor: AUTH36KRTA\u003cbr\u003eOutdoor: AOTH36KRTA\u003cbr\u003eGrille: UTG-UKTB-W\u003cbr\u003eController: UTY-LBTYC\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-sheets-root=\"1\" data-sheets-baot=\"1\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"495\"\u003e\n\u003ccol width=\"129\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor unit\u003c\/td\u003e\n\u003ctd\u003eAUTH36KRTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eAOTH36KRTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Type\u003c\/td\u003e\n\u003ctd\u003eReverse Cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source V\/Ph\/Hz\u003c\/td\u003e\n\u003ctd\u003e400 \/ 3 \/ 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity kW (Rated (Min – Max))\u003c\/td\u003e\n\u003ctd\u003e10.00 (2.8 – 11.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity kW (Rated (Min – Max))\u003c\/td\u003e\n\u003ctd\u003e11.20 (2.7 – 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Cooling kW (Rated (Min – Max))\u003c\/td\u003e\n\u003ctd\u003e3.11 (4.11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Heating kW (Rated (Min – Max))\u003c\/td\u003e\n\u003ctd\u003e3.11 (4.11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER Cooling kW\/kW\u003c\/td\u003e\n\u003ctd\u003e3.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP Heating kW\/kW\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStar Rating Cooling (0-10) (Hot \/ Average \/ Cold)\u003c\/td\u003e\n\u003ctd\u003e3 \/ 3 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStar Rating Heating (0-10) (Hot \/ Average \/ Cold)\u003c\/td\u003e\n\u003ctd\u003e3.5 \/ 2.5 \/ 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cooling Seasonal Performance Factor Residential kW (Hot \/ Average \/ Cold)\u003c\/td\u003e\n\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e4.819 \/ 4.591 \/ 4.896\u003c\/div\u003e\u003c\/div\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Seasonal Performance Factor Residential kW (Hot \/ Average \/ Cold)\u003c\/td\u003e\n\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e5.186 \/ 5.407 \/ 5.863\u003c\/div\u003e\u003c\/div\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cooling Seasonal Performance Factor Commercial kW (Hot \/ Average \/ Cold)\u003c\/td\u003e\n\u003ctd\u003e\u003cdiv\u003e\u003cdiv\u003e5.186 \/ 5.407 \/ 5.863\u003c\/div\u003e\u003c\/div\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Seasonal Performance Factor Commercial kW (Hot \/ Average \/ Cold)\u003c\/td\u003e\n\u003ctd\u003e5.036 \/ 4.53 \/ 3.743\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning Current amps (Cooling \/ Heating)\u003c\/td\u003e\n\u003ctd\u003e5.2 \/ 4.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture Removal l\/hr\u003c\/td\u003e\n\u003ctd\u003e3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Sound Pressure Cooling dBA (High \/ Quiet)\u003c\/td\u003e\n\u003ctd\u003e44 \/ 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Sound Pressure Heating dBA (High \/ Quiet)\u003c\/td\u003e\n\u003ctd\u003e44 \/ 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Sound Pressure dBA (Cooling \/ Heating)\u003c\/td\u003e\n\u003ctd\u003e53 \/ 53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Sound Power dBA\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Circulation (Indoor – High Fan) Cooling l\/sec\u003c\/td\u003e\n\u003ctd\u003e486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Circulation (Indoor – High Fan) Heating l\/sec\u003c\/td\u003e\n\u003ctd\u003e586\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Unit Dimensions mm (Height x Width x Depth)\u003c\/td\u003e\n\u003ctd\u003e288 x 840 x 840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Unit Weight kg\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions mm (Height x Width x Depth)\u003c\/td\u003e\n\u003ctd\u003e788 x 940 x 320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight kg\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiping Connects mm Ø (Liquid \/ Gas)\u003c\/td\u003e\n\u003ctd\u003e9.52 \/ 15.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe Length m (Max (Precharged))\u003c\/td\u003e\n\u003ctd\u003e50 (30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference m\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Range Cooling °CDB (Min to Max)\u003c\/td\u003e\n\u003ctd\u003e-10 to 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Range Heating °CDB (Min to Max)\u003c\/td\u003e\n\u003ctd\u003e-15 to 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Amount g\u003c\/td\u003e\n\u003ctd\u003e1,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fujitsu","offers":[{"title":"Default Title","offer_id":47123497189532,"sku":"SET-AUTH36KRTA-3PH-YC","price":4731.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0248\/9756\/files\/Complete_Set_4_30ed726b-05ad-4209-8bfd-acd3702034c8.png?v=1782728312","url":"https:\/\/checkout.airconditioningexperts.com.au\/products\/fujitsu-set-auth36krta-3ph-yc-10kw-inverter-cassette-split-systems-1-phase-r32","provider":"Air Conditioning Experts","version":"1.0","type":"link"}