{"product_id":"fujitsu-set-auth24krta-t5-7-1kw-inverter-cassette-split-systems-1-phase-r32","title":"Fujitsu SET-AUTH24KRTA-T5 7.1kW Inverter Cassette Split Systems 1 Phase | R32","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch2\u003eFujitsu SET-AUTH24KRTA-T5 7.1kW Inverter Cassette Split System\u003c\/h2\u003e\n\u003cp\u003eThe Fujitsu SET-AUTH24KRTA-T5 7.1kW inverter cassette split system air conditioner offers efficient cooling and heating with a sleek design. Powered by a single-phase system and utilising R32 refrigerant, this unit provides a cooling capacity of 7.1kW and heating capacity of 8.0kW. It features quiet operation, advanced moisture removal and a user-friendly wired controller for optimal climate control. Suitable for residential and commercial spaces, it ensures comfort and reliability.\u003c\/p\u003e\n\n\u003cp\u003eIndoor: AUTH24KRTA\u003cbr\u003eOutdoor: AOTH24KBTA\u003cbr\u003eGrille: UTG-UKTB-W\u003cbr\u003eController: UTY-RNRYT5\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor unit\u003c\/td\u003e\n    \u003ctd\u003eAUTH24KRTA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor unit\u003c\/td\u003e\n    \u003ctd\u003eAOTH24KBTA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperation Type\u003c\/td\u003e\n    \u003ctd\u003eReverse Cycle\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePower Source\u003c\/td\u003e\n    \u003ctd\u003e230 \/ 1 \/ 50\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCooling Capacity\u003c\/td\u003e\n    \u003ctd\u003e7.10 (1.8 – 8.1)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHeating Capacity\u003c\/td\u003e\n    \u003ctd\u003e8.00 (2 – 9.1)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eInput Power Cooling\u003c\/td\u003e\n    \u003ctd\u003e2.15 (2.73)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eInput Power Heating\u003c\/td\u003e\n    \u003ctd\u003e2.1 (2.59)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEER Cooling\u003c\/td\u003e\n    \u003ctd\u003e3.3\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCOP Heating\u003c\/td\u003e\n    \u003ctd\u003e3.81\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eStar Rating Cooling\u003c\/td\u003e\n    \u003ctd\u003e3 \/ 3 \/ 3\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eStar Rating Heating\u003c\/td\u003e\n    \u003ctd\u003e3.5 \/ 2.5 \/ 2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTotal Cooling Seasonal Performance Factor Residential\u003c\/td\u003e\n    \u003ctd\u003e4.995 \/ 4.697 \/ 4.992\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHeating Seasonal Performance Factor Residential\u003c\/td\u003e\n    \u003ctd\u003e5.398 \/ 5.615 \/ 6.087\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTotal Cooling Seasonal Performance Factor Commercial\u003c\/td\u003e\n    \u003ctd\u003e5.398 \/ 5.615 \/ 6.087\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHeating Seasonal Performance Factor Commercial\u003c\/td\u003e\n    \u003ctd\u003e5.237 \/ 4.747 \/ 4.131\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRunning Current\u003c\/td\u003e\n    \u003ctd\u003e9.4 \/ 9.2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMoisture Removal\u003c\/td\u003e\n    \u003ctd\u003e3.1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor Sound Pressure Cooling\u003c\/td\u003e\n    \u003ctd\u003e35 \/ 30\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor Sound Pressure Heating\u003c\/td\u003e\n    \u003ctd\u003e35 \/ 30\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor Sound Pressure\u003c\/td\u003e\n    \u003ctd\u003e48 \/ 50\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor Sound Power\u003c\/td\u003e\n    \u003ctd\u003e68\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eAir Circulation (Indoor – High Fan) Cooling\u003c\/td\u003e\n    \u003ctd\u003e300\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eAir Circulation (Indoor – High Fan) Heating\u003c\/td\u003e\n    \u003ctd\u003e300\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor Unit Dimensions\u003c\/td\u003e\n    \u003ctd\u003e246 x 840 x 840\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIndoor Unit Weight\u003c\/td\u003e\n    \u003ctd\u003e24.00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor Unit Dimensions\u003c\/td\u003e\n    \u003ctd\u003e716 x 820 x 315\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n    \u003ctd\u003e42.00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eGrill Weight\u003c\/td\u003e\n    \u003ctd\u003e6.00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePiping Connects\u003c\/td\u003e\n    \u003ctd\u003e6.35 \/ 12.7\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePipe Length\u003c\/td\u003e\n    \u003ctd\u003e30 (20)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMax Height Difference\u003c\/td\u003e\n    \u003ctd\u003e25\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperation Range Cooling\u003c\/td\u003e\n    \u003ctd\u003e-10 to 50\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperation Range Heating\u003c\/td\u003e\n    \u003ctd\u003e-15 to 24\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n    \u003ctd\u003eR32\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRefrigerant Amount\u003c\/td\u003e\n    \u003ctd\u003e1,250\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Fujitsu","offers":[{"title":"Default Title","offer_id":47123495616668,"sku":"SET-AUTH24KRTA-T5","price":3489.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0248\/9756\/files\/Complete_Set_4_363af43c-29e4-4bab-8080-b445d1e2c839.png?v=1782728293","url":"https:\/\/checkout.airconditioningexperts.com.au\/products\/fujitsu-set-auth24krta-t5-7-1kw-inverter-cassette-split-systems-1-phase-r32","provider":"Air Conditioning Experts","version":"1.0","type":"link"}