{"product_id":"fujitsu-set-abth45krta-3ph-t5-12-5kw-inverter-floor-console-system-3-phase-r32","title":"FUJITSU SET-ABTH45KRTA-3PH-T5 12.5KW Inverter Floor Console System 3 Phase | R32","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch2\u003eThe Fujitsu SET-ABTH45KRTA 12.5kW Inverter Floor Console System\u003c\/h2\u003e\n\u003cp\u003eThe Fujitsu SET-ABTH45KRTA 12.5kW Inverter Floor Console split system offers powerful climate control with a 3-phase power supply, reverse cycle operation, and R32 refrigerant. With an impressive 13.00 kW cooling and 15.50 kW heating capacity, this system ensures optimal comfort for any residential or commercial setting. Featuring quiet operation and efficient energy use, it's designed for seamless integration into diverse environments, providing reliable and precise temperature management.\u003c\/p\u003e\n\n\u003cp\u003eIndoor: ABTH45KRTA\u003cbr\u003eOutdoor: AOTH45KRTA\u003cbr\u003eRemote: Wired Remote UTY-RNRYT5 included\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable class=\"table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr class=\"header-row\"\u003e\n      \u003ctd\u003eIndoor unit\u003c\/td\u003e\n      \u003ctd\u003eABTH54KRTA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"header-row\"\u003e\n      \u003ctd\u003eOutdoor unit\u003c\/td\u003e\n      \u003ctd\u003eAOTH54KRTA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eOperation Type\u003c\/td\u003e\n      \u003ctd\u003eReverse Cycle\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003ePower Source\u003c\/td\u003e\n      \u003ctd\u003e400 \/ 3 \/ 50\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eCooling Capacity\u003c\/td\u003e\n      \u003ctd\u003e13.00 (4.5 – 15)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eHeating Capacity\u003c\/td\u003e\n      \u003ctd\u003e15.50 (4.7 – 18)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eInput Power Cooling\u003c\/td\u003e\n      \u003ctd\u003e4.31 (5.19)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eInput Power Heating\u003c\/td\u003e\n      \u003ctd\u003e4.25 (5.23)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eEER Cooling\u003c\/td\u003e\n      \u003ctd\u003e3.02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eCOP Heating\u003c\/td\u003e\n      \u003ctd\u003e3.65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eStar Rating Cooling\u003c\/td\u003e\n      \u003ctd\u003e3 \/ 2.5 \/ 3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eStar Rating Heating\u003c\/td\u003e\n      \u003ctd\u003e3 \/ 2 \/ 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eTotal Cooling Seasonal Performance Factor Residential\u003c\/td\u003e\n      \u003ctd\u003e4.523 \/ 4.322 \/ 4.615\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eHeating Seasonal Performance Factor Residential\u003c\/td\u003e\n      \u003ctd\u003e4.728 \/ 3.581 \/ 2.986\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eTotal Cooling Seasonal Performance Factor Commercial\u003c\/td\u003e\n      \u003ctd\u003e4.865 \/ 5.077 \/ 5.508\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eHeating Seasonal Performance Factor Commercial\u003c\/td\u003e\n      \u003ctd\u003e4.739 \/ 4.082 \/ 3.533\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eRunning Current\u003c\/td\u003e\n      \u003ctd\u003e7 \/ 6.6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eMoisture Removal\u003c\/td\u003e\n      \u003ctd\u003e5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eIndoor Sound Pressure Cooling\u003c\/td\u003e\n      \u003ctd\u003e48 \/ 38\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eIndoor Sound Pressure Heating\u003c\/td\u003e\n      \u003ctd\u003e48 \/ 38\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eOutdoor Sound Pressure\u003c\/td\u003e\n      \u003ctd\u003e55 \/ 57\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eOutdoor Sound Power\u003c\/td\u003e\n      \u003ctd\u003e72\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eAir Circulation (Indoor – High Fan) Cooling\u003c\/td\u003e\n      \u003ctd\u003e583\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eAir Circulation (Indoor – High Fan) Heating\u003c\/td\u003e\n      \u003ctd\u003e583\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eIndoor Unit Dimensions\u003c\/td\u003e\n      \u003ctd\u003e235 x 1700 x 705\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eIndoor Unit Weight\u003c\/td\u003e\n      \u003ctd\u003e38.00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eOutdoor Unit Dimensions\u003c\/td\u003e\n      \u003ctd\u003e998 x 940 x 320\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n      \u003ctd\u003e67.00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003ePiping Connects\u003c\/td\u003e\n      \u003ctd\u003e9.52 \/ 15.88\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003ePipe Length\u003c\/td\u003e\n      \u003ctd\u003e50 (30)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eMax Height Difference\u003c\/td\u003e\n      \u003ctd\u003e30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eOperation Range Cooling\u003c\/td\u003e\n      \u003ctd\u003e-10 to 50\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eOperation Range Heating\u003c\/td\u003e\n      \u003ctd\u003e-15 to 24\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n      \u003ctd\u003eR32\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr class=\"normal\"\u003e\n      \u003ctd\u003eRefrigerant Amount\u003c\/td\u003e\n      \u003ctd\u003e2,180\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fujitsu","offers":[{"title":"Default Title","offer_id":47123493027996,"sku":"SET-ABTH45KRTA-3PH-T5","price":4785.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0248\/9756\/files\/TS.png?v=1782728146","url":"https:\/\/checkout.airconditioningexperts.com.au\/products\/fujitsu-set-abth45krta-3ph-t5-12-5kw-inverter-floor-console-system-3-phase-r32","provider":"Air Conditioning Experts","version":"1.0","type":"link"}