{"product_id":"daikin-sky-air-ftxc60a-av-6kw-reverse-cycle-split-system-air-conditioner-1-phase-copy","title":"DAIKIN SKY AIR FTXC60A-AV 6kW Reverse Cycle Split System Air Conditioner | 1 Phase","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch2\u003eDaikin Sky Air FTXC60A-AV 6kW Reverse Cycle Split System Air Conditioner\u003c\/h2\u003e\n\u003cp\u003eThe Daikin Sky Air FTXC60A-AV is a 6kW reverse cycle split system air conditioner designed with a compact and sophisticated style, perfect for modern Australian homes. With fresh white flaps that close neatly when not in use, this unit ensures both comfort and aesthetic appeal. Featuring auto swing and wide-angle louvres, it distributes air evenly across the room. Its powerful airflow reaches the far side of long rooms with ease. Additionally, it offers design and installation flexibility with 6-direction refrigerant piping and easy maintenance access. The system supports interlock control for energy efficiency and connects to centralised control systems effortlessly. Experience easy cleaning with a removable, washable grille and non-flocking flaps that resist dirt. This air conditioner promises comfort, efficiency and a sleek design for any space.\u003c\/p\u003e\n\u003cp\u003eIndoor: FTXC60AV1A\u003cbr\u003eOutdoor: RXC60AV1A\u003cbr\u003eController: Includes BRC1E63 Controller\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eModel Name\u003c\/td\u003e\n      \u003ctd\u003eIndoor unit\u003c\/td\u003e\n      \u003ctd\u003eFTXC60AV1A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eOutdoor unit\u003c\/td\u003e\n      \u003ctd\u003eRXC60AV1A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\"\u003ePower supply\u003c\/td\u003e\n      \u003ctd\u003e1 Phase, 220-240V, 50Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eCooling capacity (Rated Min. – Max.)\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e6.0 (1.4-7.1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eHeating capacity (Rated Min. – Max.)\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e7.1 (1.4-8.0)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003ePower consumption\u003c\/td\u003e\n      \u003ctd\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e1.80\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e2.05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eEER\u003c\/td\u003e\n      \u003ctd\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003ekW\/kW\u003c\/td\u003e\n      \u003ctd\u003e3.34\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eCOP\u003c\/td\u003e\n      \u003ctd\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003ekW\/kW\u003c\/td\u003e\n      \u003ctd\u003e3.46\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eAEER\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003e3.24\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eACOP\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003e3.38\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"3\"\u003eTCSPF (Cooling) Commercial \/ Residential\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eHot\u003c\/td\u003e\n      \u003ctd\u003e5.02 \/ 4.58\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eAverage\u003c\/td\u003e\n      \u003ctd\u003e4.99 \/ 3.94\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eCold\u003c\/td\u003e\n      \u003ctd\u003e5.29 \/ 3.98\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"3\"\u003eHSPF (Heating) Commercial \/ Residential\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eHot\u003c\/td\u003e\n      \u003ctd\u003e5.16 \/ 5.13\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eAverage\u003c\/td\u003e\n      \u003ctd\u003e4.71 \/ 4.38\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eCold\u003c\/td\u003e\n      \u003ctd\u003e4.22 \/ 3.84\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"9\"\u003eIndoor unit\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eColour\u003c\/td\u003e\n      \u003ctd\u003eFresh white\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003eAirflow rate (H \/ M \/ L)\u003c\/td\u003e\n      \u003ctd\u003e\/s\u003c\/td\u003e\n      \u003ctd\u003e300 \/ 267 \/ 233\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003em3\/min\u003c\/td\u003e\n      \u003ctd\u003e18.0 \/ 16.0 \/ 14.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eSound pressure level (H \/ M \/ L)\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e45.0 \/ 42.0 \/ 40.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eSound power level (H \/ M \/ L)\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e61 \/ 58 \/ 56\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eDimensions (HXWXD)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003e290X1,050X238\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eMachine weight\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd\u003e13\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"2\"\u003eCertified operation range\u003c\/td\u003e\n      \u003ctd\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003e°CWB\u003c\/td\u003e\n      \u003ctd\u003e14 to 25\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003e°CDB\u003c\/td\u003e\n      \u003ctd\u003e15 to 27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutdoor\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eColour\u003c\/td\u003e\n      \u003ctd\u003eIvory White\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"10\"\u003eunit\u003c\/td\u003e\n      \u003ctd rowspan=\"2\"\u003eCompressor\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eType\u003c\/td\u003e\n      \u003ctd\u003eHermetically sealed swing type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMotor output\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e1.3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eRefrigerant charge (R-32)\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd\u003e1.35 (Charged for 30 m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"2\"\u003eSound pressure level\u003c\/td\u003e\n      \u003ctd\u003eCooling \/ Heating\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e48 \/ 51\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNight quiet mode\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e44\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eSound power level\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e68\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eDimensions (HXWXD)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003e595X845X300\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eMachine weight\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd\u003e45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"2\"\u003eCertified operation range\u003c\/td\u003e\n      \u003ctd\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003e°CDB\u003c\/td\u003e\n      \u003ctd\u003e-5 to 50\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003e°CWB\u003c\/td\u003e\n      \u003ctd\u003e-15 to 15.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"4\"\u003ePiping connections\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eLiquid (Flare)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003eo\/ 6.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eGas (Flare)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003eo\/ 12.7\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"2\"\u003eDrain\u003c\/td\u003e\n      \u003ctd\u003eIndoor unit\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003eVP13 (I.D.o\/ 13XO.D. o\/ 18)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutdoor unit\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003eo\/ 26.0 (Hole)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eMax. interunit piping length\u003c\/td\u003e\n      \u003ctd\u003em\u003c\/td\u003e\n      \u003ctd\u003e50 (Equivalent length 70)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eMax. installation height difference\u003c\/td\u003e\n      \u003ctd\u003em\u003c\/td\u003e\n      \u003ctd\u003e30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\"\u003eHeat insulation\u003c\/td\u003e\n      \u003ctd\u003eBoth liquid and gas piping\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":46590699896988,"sku":null,"price":2031.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0248\/9756\/files\/FTXC50A-AV_512db4d6-be03-4b0f-b609-3016f469fd7c.png?v=1774566555","url":"https:\/\/checkout.airconditioningexperts.com.au\/products\/daikin-sky-air-ftxc60a-av-6kw-reverse-cycle-split-system-air-conditioner-1-phase-copy","provider":"Air Conditioning Experts","version":"1.0","type":"link"}