{"product_id":"daikin-sky-air-faa100b-vc2y-10kw-reverse-cycle-split-system-air-conditioner-3-phase","title":"DAIKIN SKY AIR FAA100B-VC2Y 10kW Reverse Cycle Split System Air Conditioner | 3 Phase","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch2\u003eDaikin Sky Air FAA100B-VC2Y 10kW Reverse Cycle Split System Air Conditioner\u003c\/h2\u003e\n\u003cp\u003eExperience unparalleled comfort with the Daikin Sky Air FAA100B-VC2Y. This 10kW split system air conditioner offers a sleek, compact design complemented by a sophisticated fresh white finish. It boasts advanced features like auto swing, wide-angle louvers and a programme 'Dry' mode for optimised dehumidification. Designed for both cooling and heating, it ensures even temperature distribution across your space. With flexible installation options and easy maintenance, this system is perfect for both residential and commercial applications. Enjoy energy savings with interlock control and seamless integration with centralised control systems.\u003c\/p\u003e\n\n\u003cp\u003eIndoor: FAA100BVMA\u003cbr\u003eOutdoor: RZAV100C2Y1\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eModel Name\u003c\/td\u003e\n      \u003ctd\u003eIndoor unit\u003c\/td\u003e\n      \u003ctd\u003eFAA100BVMA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eOutdoor unit\u003c\/td\u003e\n      \u003ctd\u003eRZAV100C2Y1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\"\u003ePower supply\u003c\/td\u003e\n      \u003ctd\u003e3 Phase, 380-415V, 50Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eCooling capacity Rated (Min. – Max.)\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e10.0 (5.0-11.2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eHeating capacity Rated (Min. – Max.)\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e11.2 (5.1-12.5)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003ePower consumption\u003c\/td\u003e\n      \u003ctd\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e3.11\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e3.48\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eEER\u003c\/td\u003e\n      \u003ctd\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003ekW\/kW\u003c\/td\u003e\n      \u003ctd\u003e3.22\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eCOP\u003c\/td\u003e\n      \u003ctd\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003ekW\/kW\u003c\/td\u003e\n      \u003ctd\u003e3.22\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eAEER\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003e3.16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eACOP\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003e3.17\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eTCSPF (Cooling) Commercial \/ Residential\u003c\/td\u003e\n      \u003ctd\u003eHot\u003c\/td\u003e\n      \u003ctd\u003e5.03 \/ 4.63\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAverage\u003c\/td\u003e\n      \u003ctd\u003e5.12 \/ 4.17\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCold\u003c\/td\u003e\n      \u003ctd\u003e5.48 \/ 4.31\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eHSPF (Heating) Commercial \/ Residential\u003c\/td\u003e\n      \u003ctd\u003eHot\u003c\/td\u003e\n      \u003ctd\u003e4.66 \/ 4.64\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAverage\u003c\/td\u003e\n      \u003ctd\u003e4.25 \/ 3.95\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCold\u003c\/td\u003e\n      \u003ctd\u003e3.77 \/ 3.42\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIndoor unit\u003c\/td\u003e\n      \u003ctd\u003eColour\u003c\/td\u003e\n      \u003ctd\u003eFresh White\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAirflow rate (H \/ M \/ L)\u003c\/td\u003e\n      \u003ctd\u003e\/s\u003c\/td\u003e\n      \u003ctd\u003e433 \/ 383 \/ 317\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003em3\/min\u003c\/td\u003e\n      \u003ctd\u003e26.0 \/ 23.0 \/ 19.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSound pressure level (H \/ M \/ L)\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e49.0 \/ 45.0 \/ 41.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (HXWXD)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003e340X1,200X240\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMachine weight\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd\u003e17\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCertified operation range\u003c\/td\u003e\n      \u003ctd\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003e°CWB\u003c\/td\u003e\n      \u003ctd\u003e14 to 25\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003e°CDB\u003c\/td\u003e\n      \u003ctd\u003e15 to 27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutdoor\u003c\/td\u003e\n      \u003ctd\u003eColour\u003c\/td\u003e\n      \u003ctd\u003eIvory White\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eunit\u003c\/td\u003e\n      \u003ctd\u003eCompressor\u003c\/td\u003e\n      \u003ctd\u003eType\u003c\/td\u003e\n      \u003ctd\u003eHermetically sealed swing type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMotor output\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd\u003e3.30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRefrigerant charge (R-32)\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd\u003e3.75 (Charged for 30 m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSound pressure level\u003c\/td\u003e\n      \u003ctd\u003eCooling \/ Heating\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e51 \/ 53\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNight quiet mode\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e47\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSound power level\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd\u003e70\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (HXWXD)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003e1,430X940X320\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMachine weight\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd\u003e93\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCertified operation range\u003c\/td\u003e\n      \u003ctd\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003e°CDB\u003c\/td\u003e\n      \u003ctd\u003e-5 to 50\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003e°CWB\u003c\/td\u003e\n      \u003ctd\u003e-15 to 15.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePiping connections\u003c\/td\u003e\n      \u003ctd\u003eLiquid (Flare)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003eo\/ 9.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGas (Flare)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003eo\/ 15.9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDrain\u003c\/td\u003e\n      \u003ctd\u003eIndoor unit\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003eVP13 (I.D. o\/ 13XO.D. o\/ 18)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutdoor unit\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd\u003eo\/ 25.0 (Hole)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. interunit piping length\u003c\/td\u003e\n      \u003ctd\u003em\u003c\/td\u003e\n      \u003ctd\u003e75 (Equivalent length 90)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. installation height difference\u003c\/td\u003e\n      \u003ctd\u003em\u003c\/td\u003e\n      \u003ctd\u003e30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeat insulation\u003c\/td\u003e\n      \u003ctd\u003eBoth liquid and gas piping\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":46590699471004,"sku":"FAA100B-VC2Y","price":4979.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0248\/9756\/files\/FTXC50A-AV.png?v=1774566493","url":"https:\/\/checkout.airconditioningexperts.com.au\/products\/daikin-sky-air-faa100b-vc2y-10kw-reverse-cycle-split-system-air-conditioner-3-phase","provider":"Air Conditioning Experts","version":"1.0","type":"link"}