{"product_id":"daikin-fca100c-vf2v-10-0kw-premium-inverter-reverse-cycle-cassette-system-1-phase","title":"DAIKIN FCA100C-VF2V 10.0kW Premium Inverter Reverse Cycle Cassette System | 1 Phase","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch2\u003eDAIKIN FCA100C-VF2V 10.0kW Premium Inverter Reverse Cycle Cassette System\u003c\/h2\u003e\n\u003cp\u003eExperience superior climate control with the Daikin FCA100C-VF2V 10.0kW Premium Inverter Reverse Cycle cassette air conditioner. This advanced system provides powerful cooling and heating solutions, featuring a sleek design that integrates seamlessly into any space. Ideal for both residential and commercial environments, it offers quiet operation and energy-efficient performance. The system includes the indoor unit FCA100CVMA, outdoor unit RZAV100F2V1, and a stylish fascia with a BRC1E63 controller, ensuring optimal comfort and convenience.\u003c\/p\u003e\n\n\u003cp\u003eIndoor: FCA100CVMA\u003cbr\u003eOutdoor: RZAV100F2V1\u003cbr\u003eController: BRC1E63\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"6\"\u003eIndoor Unit\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eFCA100CVMA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"6\"\u003eOutdoor Unit\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eRZAV100C2V1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"5\"\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003eø \/ V \/ Hz\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e1 Phase, 240V, 50 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eCooling Capacity\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eRated (Min – Max)\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e10.0 (5.0 – 11.2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eHeating Capacity\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eRated (Min – Max)\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e11.2 (5.1 – 12.5)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\" rowspan=\"2\"\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e2.38\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e2.40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\" rowspan=\"2\"\u003eEnery Efficiency\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eEER\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e4.21\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eCOP\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e4.67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"11\"\u003eIndoor Unit\u003c\/td\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003eColour\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eUnit\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e–\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eDecoration Panel\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eFresh White\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\" rowspan=\"2\"\u003eAirflow Rate (H \/ HM \/ M \/ ML \/ L)\u003c\/td\u003e\n      \u003ctd\u003eL\/s\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e575 \/ 517 \/ 458 \/ 400 \/ 333\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003em³\/min\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e34.5 \/ 31.0 \/ 27.5 \/ 24.0 \/ 20.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\"\u003eSound Level (H\/M\/L)\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e45.0 \/ 42.0 \/ 39.0 \/ 36.5 \/ 34.0 \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003eDimensions (HxWxD)\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eUnit\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e298 x 840 x 840\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eDecoration Panel\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e50 x 950 x 950\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003eMachine Weight\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eUnit\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e26\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eDecoration Panel\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e5.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003eCertified Operation Range\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003e°CWB\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e14 to 25\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003e°CDB\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e15 to 27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"11\"\u003eOutdoor Unit\u003c\/td\u003e\n      \u003ctd colspan=\"4\"\u003eColour\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eIvory white\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003eCompresser\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eType\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eHermetically sealed swing type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eMotor output\u003c\/td\u003e\n      \u003ctd\u003ekW\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e3.3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\"\u003eRefrigerant Charge (R410a)\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e3.75 (charged for 30m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003eSound Level\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eCooling \/ Heating\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e51 \/ 53\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eNight quiet mode\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e47\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\"\u003eSound Power Level (H\/L)\u003c\/td\u003e\n      \u003ctd\u003edB(A)\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e70\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\"\u003eDimensions (HxWxD)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e1430 x 940 x 320\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"4\"\u003eMachine Weight\u003c\/td\u003e\n      \u003ctd\u003ekg\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e93\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"2\"\u003eCertified Operation range\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eCooling\u003c\/td\u003e\n      \u003ctd\u003e°CDB\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e-5 to 50\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eHeating\u003c\/td\u003e\n      \u003ctd\u003e°CWB\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e-15 to 15.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\" rowspan=\"4\"\u003ePiping Connections\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eLiquid (Flare)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eø9.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"3\"\u003eGas (Flare)\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eø15.9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"2\"\u003eDrain\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003eIndoor Unit\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eI.D. ø25 x O.D ø32\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"2\"\u003eOutdoor Unit\u003c\/td\u003e\n      \u003ctd\u003emm\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eø26.0 (Hole)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"5\"\u003eRefrigerant\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eR32\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"5\"\u003eMax, interunit piping length\u003c\/td\u003e\n      \u003ctd\u003em\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e75 (Equivalent length 90)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"5\"\u003eMax. Installation level difference\u003c\/td\u003e\n      \u003ctd\u003em\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003e30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd colspan=\"5\"\u003eHeat insulation\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"3\"\u003eBoth liquid and gas piping\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":47033261818012,"sku":"FCA100C-VF2V","price":5411.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0248\/9756\/files\/DAIKINFCASET_cd308cc0-650c-4b78-a6d6-0d069c337a73.jpg?v=1780808366","url":"https:\/\/checkout.airconditioningexperts.com.au\/products\/daikin-fca100c-vf2v-10-0kw-premium-inverter-reverse-cycle-cassette-system-1-phase","provider":"Air Conditioning Experts","version":"1.0","type":"link"}